Load Cell Protector
FEATURES
- Six wires and shield protection works with four or six wire systems
- Suitable for compression or tension cells
- Low series impedance, loadcells do not need recalibration
- NEMA®-12 (IP-55) rated, suitable for outdoor use
- Helps protect against excitation over-voltage and prevent loadcell damage
SPECIFICATIONS
| Part Number | LCP01A |
| Article Number | 701610 |
| Max Discharge Current (Imax), Shield to Ground | 10 kA 8/20 μs |
| Max Discharge Current (Imax), Signal to Shield | 0.3 kA 8/20 μs |
| Voltage Protection Level (Up), Shield to Ground | 90 V |
| Voltage Protection Level (Up), Signal to Shield | 30 V |
| Voltage Protection Level (Up), Signal to Signal | 15 V |
| Loop Resistance | 0.3 Ω |
| Technology | Silicon Avalanche Diode (SAD) |
| Material | Acrylonitrile Butadiene Styrene |
| Enclosure Rating | NEMA® 12 (IP55) |
| Depth (D) | 110 mm |
| Height (H) | 56 mm |
| Width (W) | 75 mm |
| Unit Weight | 0.25 kg |
| Temperature | -40 to 80 °C |

Documents
Download PDFFor more product information required please contact GLTM